Sitehome Favorites Postoffice 中文版
 
Patent product
By-pass Filter
Sewage Disposal Equipment
 
   
HOME > GUANGYANG PRODUCTS >
GUANGYANG PRODUCTS
 
 
MHCY chemical grease remover
 

 
Survey of MHCY Equipment:

1. Chemical grease removing is to put into chemicals and mixed, the suspended matter of grease, sinter can be separated through the action of condensation and flocculation, purifying water. When grease contained in water is 35-45mg/L and ss content is 200mgL, grease content in discharged water is less than 10mg/L and ss less than 25mg/L.

2. There are two kinds of chemicals for dosing separately, the first one is dielectric type, such as aluminum sulfate, compound polyalumino, aluminum chlorohydroxide, polymeric ferric sulfate and iron trichloride etc, that can be put into the first mixing chamber; the second one is grease flocculating agent, it is a kind of specially made high polymer grease flocculating agent that can be put into the second chamber for mixing. The two kind of chemicals should be put into in sequence separately, and both dose of the chemicals is 15mg/L and thickness is 2-3%. The two kinds of chemicals are nontoxic.

3. Sewage will be sent into the rear reaction chamber and inclined-tube sedimentation chamber after being mixed with chemicals in the first and second chambers, grease (floating grease and emulsified oil) and suspended matter can be formed into large particles and settled in the lower discharged sludge through the action of condensation and flocculation, and the clean water at the upper part can be discharged from outlet pipe through effluent weir. And water is discharged every 8 hours and each time takes 3-5 minutes, the sludge drained out can be delivered into spiral flow tank (or primary sheet iron sedimentation tank) or slag pit and delivered out with coarse grain-sheet iron or individually delivered after being thickly treated.

4. In order to easily make sludge discharge of chemical grease remover, the sewage enters into the device through spiral flow tank (or primary sheet iron sedimentation tank) can be treated with the chemical grease remover as follows:

MHCY chemical grease remover main data for all models as follows:

Ltem

Treatment capacity

T

Wet weight

Installed capacity

Remark

MHCY1

100th

13.4

70

3.71KW

-

MHCY2

200th

1923

104

3.71KW

-

MHCY-3

300th

264

141

6.31KW

-

MHCY4

400th

309

178

6.68KW

-

MHCY5

500th

355

205

7.5KW

-

MHCY6

600th

55

250

7.5KW

-


(See Table MHCY)
Note: When the water amount of treating grease contained sewage from steel rolling workshop shown in the table is referred for the disposal of grease contained sewage form continuous casting workshop, the specified disposed water amount should be multiplied with 0.8.

5. The legs of chemical grease remover and foundation can be fixed with bolt or preset steel plate at base part, which should be welded for fixing after being leveled.

6. The chemical grease remover is suitable to be positioned on ground so as to be easily controlled and drained out sludge. In the north area, the device should be put inside room so as to avoid to be frozen.

7. The chemical grease remover is equipped with one power distributor control cabinet for controlling operation of mixer, dosing device and power butterfly valve, and it also can be equipped with other kind of power distributing or pneumatic device.

 
Closed
 
 
About Us | News | Products | Projects | Jobs Copying(C)Jiangsu Guangyang Dynamic Environmentak Equipment Co.,Ltd.All Rights Reserved.